The iDTM™ range and its ecosystem
The world's only fully integrated total-immersion cooling platform, designed to deploy and operate like a familiar air-cooled rack. A universal building-block architecture, from the 19-inch rack to the container, agnostic of server manufacturers — 100 % of digital heat captured through liquid-to-liquid exchange and reusable as heating energy.
Four structural advantages
Up to 80 % less electricity
Energy powers the compute, not the building — with a real mechanical PUE below 1.02.
Deploys like an air-cooled rack
Identical provisioning, same data and power pathways. No dedicated U, no thermal limit up to 2 kW/U.
Zero water, zero emissions
No greenhouse gases, no CO₂, no microparticles. No evaporative cooling, no water towers — ever.
Fully integrated stack
iDTM™ system, proprietary 100 % biodegradable fluid, thermal management software suite with embedded AI.
iDTM DC Series
iDTM Slim DC Series
Private data center · 19"
Intelligent 20U Gen4 immersion cooling rack in 19-inch format, designed like an air-cooled rack to fit into existing rooms. Up to 2 kW/U.
iDTM COLO DC Series
Colocation · 19"
Immersed rack for colocation operators: differentiating density, auxiliary frugality and monetisable heat for the customer offering.
iDTM FAT DC Series
Public data center · 19"
Immersed rack for public data centers and large volumes, designed for the industrialisation of deployments.
iDTM OCP DC Series
Public data center · 21" OCP
21-inch OCP variant for hyperscale and open-hardware architectures.
iDTM AI DC Series
High-density AI
Immersed rack built for high-density AI: up to 8 kW/U, 100 cm IT payload depth, FlowHT modular circuit, 2 → 4 kW upgrade kit.
iDTM AIO Series
SMB / edge · all-in-one
The "data center in a box": fully integrated immersed 10U Gen4 rack, cooling and heat recovery included, running on a standard 220 V supply.
Range extensions
iC4EDGE
Edge · 20HC / 40HC containers
Single or double containerised solution, ready to connect, housing iDTM or iIBCMiners systems — from pilot site to massive deployment.
iC4EDGE 20HC
Compact edge
Compact 20-foot high-cube version: power supply, distribution, immersed systems and heat rejection integrated in a single transportable envelope.
iEXT Cooling
Extension
Thermal capacity upgrade kit for iDTM racks: 2 → 4 kW/U without replacing the system.
MSS module
Embedded supervision
Rackable embedded-intelligence module: thermoregulation, push telemetry, isolated from the IT load to reduce the attack surface.
iICE Liquid
Consumable · fluid
Proprietary 100 % biodegradable dielectric fluid. Safety data sheet supplied with every delivery; regeneration and recycling handled by Immersion Infinite.
iIBCMiners
Specialised compute · ASIC
Immersion cooling for specialised-compute ASICs, in a rack or in an iC4EDGE container.
iCM
AIO extension
Rackable cooling system adaptation for the AIO series.
iATX & iEMBARQ
Workstation · embedded
Immersion cooling for high-performance desktop PCs (iATX) and for embedded electronics (iEMBARQ).
PSU adaptation kit
Accessory
Adaptation kit for power supply units in an immersed environment.
Any building can become a data center
From edge to hyperscale: new builds, offices, warehouses, underground sites. A floor load of 1.2 t/m² and a 2.70 m ceiling height are all it takes. No chillers, no raised floors, no water towers — and full efficiency from 1 % occupancy.
A 5 MW I4DC™ data center delivers:
At equal power: 5 MW air-cooled vs I4DC™
| Criterion | Conventional air-cooled | Immersive I4DC™ |
|---|---|---|
| Build cost per MW | €10–12M | €3.6–5.4M 3 to 4× lower |
| Time to market | 15 months | 8 months up to 60% faster |
| Usable IT capacity | 2.4 MW | 5 MW 2× the compute |
| Power reaching the compute | 64% · PUE 1.57 | 93% · PUE 1.07 |
| Water consumption | 1.8 L per kW | None |
| Heat reuse | ~30% | 100% |
| Investment model | Full upfront CAPEX | "Pay as you grow" |
Every product carries its installation envelope
Structure, access, handling, electricity, thermal, environment, IT load and fluid: every product is described by a structured installation envelope — the single source used by the product sheet, the project journey and the reports.
| Family | Structured data | Effect in the platform |
|---|---|---|
| Structure | Mass, floor load, flatness, anchoring, vibrations | Checks building compatibility |
| Access | Doors, corridors, turning radius, lift, loading dock | Deliverability analysis |
| IT electricity | Power, voltage, phases, frequency, UPS/PDU, redundancy | Sizes the power supply |
| Thermal | Temperatures, flow rate, pressure, exchanger, loop, rejection | Checks heat evacuation |
| IT load | Brand, model, dimensions, mass, PSU, firmware | Establishes per-equipment compatibility |
| Fluid | Authorised reference, volume, compatibility, warranty | Guarantees use of the approved iICE fluid |